Abstract

AbstractThis article describes the design, construction, and first experimental results of a 90 m-long Hopkinson bar which can perform high strain rate tests in a combined tension–torsion state. The system configuration is analogous to the classic Hopkinson bar technique, consisting of three bars: a pre-stressed bar, an input bar, and an output bar; the sample is placed between the input and output bar. The measurement is also based on the classical three-wave method, where the incident, transmitted and reflected waves are measured. Incident compression and torsional waves are simultaneously generated by the failure of a fragile element that connects the pre-stressed bar to electromechanical actuators; the indirect Hopkinson tension bar technique is exploited, where the compression wave reaches the end of the output bar without stressing the sample and is reflected as a tensile input wave. The length of the bars is designed so that the tensile wave reaches the sample from the output bar side at the same time as the torsion wave comes from the input bar. Void tests were carried out first, for preliminary analysis of the system behaviour. Then, successful tests have been conducted on samples made of AA7075 T6, both in combined and pure tension–torsion states; it has been possible to measure the tension–torsion stress–strain curves, from which the equivalent flow stress–strain curve has been evaluated and compared to the quasi-static ones.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.