Abstract

In this paper, simulated and measured results are presented for a microwave-integrated-circuit super regenerative detector operating at 7.5 GHz and brief comparisons made to a monolithic-microwave integrated-circuit super regenerative detector operating at 34 GHz. The sensitivity of the 7.5-GHz detector was measured at -83-dBm (AM, 1 kHz, 100 % mod) RF signal for 12 dB (signal + noise + distortion)/(noise + distortion). Simulation results show that, to produce a sensitive super regenerative detector, a high rate of change in loop gain of the oscillator circuit with respect to the gate bias (quenching) voltage and a high maximum loop gain at the point of detection is required. It has also been shown, by simulation and measurement, that the detection frequency of the super regenerative detector is lower than the normal free-running oscillation frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.