Introduction: The aim of the present study is to describe a case report of lower molars substitution with 2 different dental implants. One with a DAE surface and one with a type 1 collagen coated surface. Case presentation: In the present study, a 54-year-old man presented the absence of the first and second molars both on the left and on the right mandible. After clinical and radiographic evaluation, implant therapy was chosen to substitute the missing teeth. On the right mandible, a DAE surface implant was placed while on the left mandible, a bovine Type 1 collagen of dermal origin (custom made medical device) surface implant was placed. A radiographic 6 years follow up was performed. Discussion: The Type 1 collagen coated surface dental implant did not show any marginal bone loss after 6 years, moreover, it showed a bone gain after 3 months from its placement and kept it for 6 years while the traditional surface implant showed an immediate marginal bone loss.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.