Abstract

In this paper, a 5th and 7th harmonic suppression technique for a 2-level VSI fed IM drive, by using capacitive filtering is proposed. A capacitor fed 2-level inverter is used on an open-end winding induction motor to suppress all 5th and 7th order harmonics. A PWM scheme that maintains the capacitor voltage, while suppressing the harmonics is also proposed. The proposed scheme is valid for the entire modulation range, including overmodulation and six-step mode of operation of the main inverter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.