Abstract

Fabrication of posts and cores for fixed partial denture (FPD) and removable partial denture (RPD) abutment restorations is common in dentistry. The biocompatibility of various post and core techniques with the restorations was clinically evaluated according to location and function. In this study, 154 post and core constructions for 150 patients were observed for a 3-year period to determine if the function of the original restorations remained unsatisfactory. The following techniques were included: (1) screw post and light-curing composite resins, (2) cemented post with parallel sides and light-curing composite resins, and (3) a cast and core technique. Seventeen of the 154 restorations failed; four failures were attributed to root fractures, three to radicular caries, and five to crown dislodgment, while five failures were from detachment of the post and core from the root. The statistical analysis revealed that only the factor “type of abutment” (RPDs and FPDs) had some effect on the failure of the restorations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.