Abstract
This study aimed to describe a novel technique to facilitate intrascleral fixation of the intraocular lens (IOL). Two 27-gauge trocars were placed at an angle of 180° and a distance of 2 mm from the corneal limbus. A silicone microtube with an external diameter of 0.2 mm was introduced through a sclerocorneal incision and withdrawn via a trocar using retinal forceps. The tips of the IOL haptics were connected to the microtube. After the implantation of the IOL into the chamber, the haptics were externalized through the scleral site by pulling the microtubes. Each tip of the haptics was flanged and buried into the scleral tunnel. The IOL was successfully placed with this method without any complications. This study presented a novel technique for intrascleral IOL fixation using a silicone microtube. We believe that our technique might increase surgical safety and help decrease the operative time for both anterior and posterior segment techniques.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.