Abstract

The safety and effectiveness of an absorbable implant for lateral cartilage support have been recently demonstrated in subjects with nasal valve collapse (NVC) at 12 months postprocedure. This follow-up study aimed to assess whether the safety and effectiveness of the implant persist in these patients for 24 months after the procedure. Thirty subjects with Nasal Obstruction Symptom Evaluation (NOSE) score ≥ 55 and isolated NVC were treated; 14 cases were performed in an operating suite under general anesthesia and 16 cases were performed in a clinic-based setting under local anesthesia. The implant, a polylactic acid copolymer, was placed with a delivery tool within the nasal wall to provide lateral cartilage support. Subjects were followed up through 24 months postprocedure. Fifty-six implants were placed in 30 subjects. The mean preoperative NOSE score was 76.7 ± 14.8, with a range of 55 to 100. At 24 months, the mean score was 32.0 ± 29.3, reflecting an average within-patient reduction of -44.0 ± 31.1 points. There were no device-related adverse events in the 12 to 24 months period. There were five subjects who exited the study prior to the 24-month follow-up. Four of the five subjects who exited were elected for further intervention and one subject was lost to follow-up. This study demonstrates safety of an absorbable implant for lateral nasal wall support and symptom improvement in some subjects with NVC at 24 months postprocedure.

Highlights

  • Marion San Nicoló, MD1 Klaus Stelter, MD2 Haneen Sadick, MD3 Murat Bas, MD4 Alexander Berghaus, MD1

  • Thirty subjects with Nasal Obstruction Symptom Evaluation (NOSE) score ! 55 and isolated nasal valve collapse (NVC) were treated; 14 cases were performed in an operating suite under general anesthesia and 16 cases were performed in a clinic-based setting under local anesthesia

  • Adults with NVC identified as the primary contributor to Nasal airway obstruction (NAO) with a Nasal Obstruction Symptom Evaluation (NOSE) score ! 55 were included

Read more

Summary

Introduction

Marion San Nicoló, MD1 Klaus Stelter, MD2 Haneen Sadick, MD3 Murat Bas, MD4 Alexander Berghaus, MD1. The safety and effectiveness of an absorbable implant for lateral cartilage support have been recently demonstrated in subjects with nasal valve collapse (NVC) at 12 months postprocedure. This follow-up study aimed to assess whether the safety and effectiveness of the implant persist in these patients for 24 months after the procedure. This study demonstrates safety of an absorbable implant for lateral nasal wall support and symptom improvement in some subjects with NVC at 24 months postprocedure. As the material is being absorbed over time, in this study, patients were followed up from 12 to 24 months postprocedure to further examine the long-term safety and effectiveness of the implant

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.