Abstract
This paper presents the design strategy, implementation, and experimental results of a power-efficient third-order low-pass /spl Sigma//spl Delta/ analog-to-digital converter (ADC) using a continuous-time (CT) loop filter. The loop filter has been implemented by using active RC integrators. Several power optimizations, design requirements, and performance limitations relating to circuit nonidealities in the CT modulator are presented. The influence of the low supply voltage on the various building blocks such as the amplifier as well as on the overall /spl Sigma//spl Delta/ modulator is discussed. The ADC was implemented in a 3.3-V 0.5-/spl mu/m CMOS technology with standard threshold voltages. Measurements of the low-power 1.5-V CT /spl Sigma//spl Delta/ ADC show a dynamic range and peak signal-to-noise-plus-distortion ratio of 80 and 70 dB, respectively, in a bandwidth of 25 kHz. The measured power consumption is only 135 /spl mu/W from a single 1.5-V power supply.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.