Abstract

Design calculations of thermohydraulic parameters of the secondary target of the intense neutron source (INS) based on muon-catalyzed fusion (μCF) (the μCF-INS) are presented for a liquid deuterium-tritium (D-T) mixture. The synthesizer is connected to an external cooler by input and output pipelines. The optimal mixture composition, synthesizer layout, and dimensions are determined. The possibility of creating a D-T mixture flow with a quasi-uniform velocity distribution is demonstrated. Possible vortexes were found to be eliminated by installation of corresponding hydraulic resistance in the shape of a spherical shell segment. At the μCF-INS operation with its design parameters [neutron flux as high as 1014 n/(cm2·s)], the total heat deposit in the D-T mixture due to fusion and charged-particle ionization losses is estimated at ~117 kW. However, even at such conditions, with the appropriate synthesizer geometry and mass flow rate, the mixture temperature does not exceed the boiling point in any part of the synthesizer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.