Abstract

In a 12- to 18-year radiographic follow-up study of 95 Charnley low-friction total hip arthroplasties (THA), there was a statistically significant correlation between location of the center of rotation of the total hip prosthesis (notably the element horizontal distance cup to tear-drop) and long-term, unfavorable, radiographic signs, such as acetabular and stem demarcation, cup wear, cup migration, subsidence of the stem, and calcar resorption. Small differences, as little as 2 mm, in the placement of the cup in relation to anatomic landmarks were responsible for these findings. A logistical regression analysis showed that the horizontal distance cup to teardrop was the most significant parameter influencing long-term unfavorable radiographic signs of a THA in comparison with the parameters of age, gender, diagnosis, and body-weight.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.