Abstract

This paper describes a 10 V Josephson Voltage Standard (JVS) direct comparison between the National Institute of Standards and Technology (NIST) and the Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (INMETRO) using automatic data acquisition. The results were in agreement to within 1.1 nV and the mean difference between the two JVSs at 10 V is 0.54 nV with a pooled combined standard uncertainty of 1.48 nV. Considering a recent JVS comparison between NIST and the Bureau International des Poids et Mesures (BIPM), the difference between INMETRO and the BIPM thus was found to be -0.26 nV with a standard uncertainty of 1.76 nV. INMETRO JVS improvements since the 2006 INMETRO-BIPM comparison are also described.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call