Abstract

Thirty-five patients with suspected chronic osteomyelitis related to an orthopaedic device had 50 99Tcm-HMPAO-labelled leucocyte scans (LS). The scan appearances were compared with the bacteriological or clinical results and gave a sensitivity and specificity of HMPAO-LS of 83 and 100%, respectively. Bacteriological examination is often inaccurate in the diagnosis of osteomyelitis and therefore we assessed the clinical utility of HMPAO-LS. When the clinical, biological and radiological data were clearly suggestive of osteomyelitis (16/50) LS was unhelpful or even misleading when falsely negative (3/16). When the clinical, biological and radiological data were poorly suggestive of osteomyelitis (20/50) or conflicting (14/50) LS was misleading in only one patient (false negative). It is concluded that HMPAO-LS should only be performed to assist in the diagnosis of chronic osteomyelitis when there is no preexisting strong suspicion based on clinical, biological and radiological signs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.