Abstract

Results of a semi-industrial (2.5 MW(th)) furnace study on a swirl-stabilized, internally fuel-staged burner are presented. The burner design relies on penetration of the internal recirculation zone of a swirl-stabilized pulverized coal primary flame with a high-momentum reburn fuel jet. A high-volatile bituminous coal was used as the primary fuel; reburn fuels included two high-volatile bituminous coals, heavy fuel oil, natural gas and coke oven gas. Process parameters investigated included primary flame zone stoichiometry, reburn fuel fraction and stoichiometry, reburn fuel velocity and injector position, and overall excess air level or tertiary air stoichiometry. For uncontrolled baseline firing, the NOx emission was 1328 ppmv (0% O2). With fuel staging, NOx emission could be reduced to < 150 ppmv (0% O2), independent of reburn fuel type. Reburn fuel fractions in the range 20–30% gave the minimum NOx levels over the range of conditions studied without significantly affecting burnout. Reburn fuel velocity and reburn injector position did not significantly affect NOx emission.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.