This study proposed an improved continuation power flow (CPF) model to calculate the load margin for voltage stability. A self-adjusting step-size controlling scheme of CPF, which is based on the iterations in the corrector and the reactive power reserve of generator buses, is presented. The load margin here is defined either by encountering the saddle node bifurcation (SNB) or the limit-induced bifurcation (LIB). To confirm the LIB, a rapid approach is proposed to calculate the sensitivity of voltage magnitude to reactive power injection change for load buses. Because CPF with distributed slack bus (DSB) could generate different load margin results corresponding to various allocations of imbalanced power, optimization techniques should be adopted in the search for maximizing the load margin. Therefore, the improved CPF is integrated with an evolutionary mechanism-based particle swarm optimization (PSO) method via coordinate transformation. Furthermore, parallel processing is deployed in the programming for high-performance computing. The case studies for the IEEE 5-bus and IEEE 14-bus test systems demonstrate the efficiency of the proposed approaches.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.