Abstract
In the reverse osmosis plants based on Dupont technology for water desalination, permeators form the basic units of the process. Each permeator consists of membranes in the form of hollow fibres housed in a cylindrical GRP shell. This work was aimed at studying the performance of shells which have been in operation for a period of 5 years, in order to assess their suitability to be reused after they have consumed their suggested lifetime. Each shell contains sharp steps at each end as a result of a circumferential groove cut on the inside tube wall. A series of strain gages were installed mainly within the region of steps at one end of the shell. It was found that as the pressure was applied, the measured strain values were particularly high in the axial direction inside the groove.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.