Abstract

BackgroundAdenoviruses (Adv) are non-enveloped viruses that can survive for long periods on environmental surfaces. However, only 1 prior publication describes an adenovirus pseudo-outbreak associated with bronchoscopes. In 1/ 2020 infectious disease physicians noted a cluster of Adv PCR-positive bronchiolar lavage (BAL) samples, which prompted an outbreak investigation.MethodsWe reviewed medical charts, clinical microbiology, procedure logs, bronchoscope reprocessing logs, bronchoscope cleaning, and high-level disinfection (HLD) practices.ResultsOn 1/28/20 an infectious diseases physician alerted infection prevention to a cluster of 5 lung transplant patients diagnosed with Adv positive BAL samples. Four out of the 5 patients had the bronchoscopy in the same bronchoscopy suite. We reviewed BAL results from all bronchoscopies performed in this suite from 11/1/19 to 1/24/20 and found a total of 10 patients with positive Adv PCR results. Eight out of the 10 patients had bronchoscopies with one of two bronchoscopes. Of all patients who had a bronchoscopy with the bronchoscope from 11/1/19 to 1/24/20 and had respiratory viral panel sent at that time, 6 of 11 (55%) who underwent procedure with Scope A and 4 of 24 (17%) who underwent procedure with Scope B had positive Adv PCR results. Sham BALs were performed on both bronchoscopes and testing for Adv was negative. However, on inspection by the manufacturer, one scope failed both wet and dry leak tests and had several physical defects. Following removal of both bronchoscopes from service we did not find any positive Adv samples from the bronchoscopy unit.ConclusionPreviously, very few pseudo-outbreaks of Adv have been linked to bronchoscopes. We identified a pseudo-outbreak of Adv associated with 2 bronchoscopes in a hospital-based bronchoscopy suite that stopped once we removed the associated bronchoscopes from the procedural unit. Bronchoscopy-related pseudo-outbreaks occur despite standardized procedures for HLD. Bronchoscopy clinics, particularly those with a high volume of immunocompromised patients, should prospectively review BAL cultures to identify unusual pathogen trends. These trends may be a sign of damaged equipment that would otherwise go undetected.Disclosures All Authors: No reported disclosures

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.