Abstract

Background: Aborted sudden cardiac death (SCD) is a common indication for cardiovascular magnetic resonance (CMR). No studies have investigated the prognostic value of late gadolinium enhancement (LGE) solely in patients with secondary prevention implantable cardioverter-defibrillators (ICD) or aborted SCD. Methods: 58 consecutive patients who had CMR and ICD implantation after aborted SCD (defined as ventricular fibrillation or ventricular tachycardia requiring electrical or chemical cardioversion) between 2006 and 2013 were identified. Clinical notes and CMR results were reviewed. Patients were scanned with a CMR protocol that included a short axis cine stack and LGE imaging with further pulse sequences depending on the clinical request. CMR images were analysed blinded to clinical data using standard software (cvi42, Circle CVI, Canada). Patients were followed up after ICD implantation at six weeks, three months and six months and then every six months. Appropriate ICD therapy was defined as any anti-tachycardia pacing (ATP) or shock therapy from the device if delivered for a ventricular arrhythmia. Results: Follow up data was available on 55/58 patients. Four patients died during the follow up period and one patient was lost to follow up after only 14 days post-implantation. Median follow up was 791 days (interquartile range 370-1142 days). 11 patients had appropriate ICD therapy. 6 had ATP only and 5 had appropriate shocks ±ATP for ventricular arrhythmias. The clinical aetiology of the aborted SCD was ischaemic heart disease (IHD) 24, primary arrhythmia 14, arrhythmogenic right ventricular cardiomyopathy 7, dilated cardiomyopathy 6, myocarditis 2 and other 5. Of 55 patients on whom clinical outcome data was available 20 patients had ejection fraction (EF) 35%. 5/20 (25%) of those with EF 35% had appropriate ICD therapies on follow up. There was no significant difference in the likelihood ratio (LR) of appropriate therapy using an EF cutoff of 35% (LR 0.48, P=0.49), confirmed on log rank analysis of Kaplan Meier curves (figure 1) (P=0.32). Of the 52 patients who had LGE imaging and clinical outcome data 32 had LGE present and 20 had no LGE. 10/32 (31%) LGE +ve patients had appropriate ICD therapies on follow up and only 1/20 (5%) LGE-ve patients had appropriate ICD therapies. LGE +ve patients were significantly more likely to have an appropriate ICD therapy on follow up (LR 5.97, P=0.015), confirmed on log rank analysis of Kaplan Meier curves (P=0.036). Conclusion: In patients who have suffered aborted SCD, CMR is able to identify patients at risk of future arrhythmic events according to the presence or absence of LGE. ![Graphic][1] Figure 1 Kaplan Meier curves showing freedom from appropriate ICD therapy with patients stratified according to EF (below) and presence of LGE (above). Each horizontal line represents a censored subject. [1]: /embed/inline-graphic-1.gif

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call