Abstract
BackgroundCentral line associated bloodstream infections (CLABSI) are a recognized complication of all central venous access devices including pulmonary artery catheters (PAC). At our institution, PACs are utilized frequently, often for prolonged durations, for patients with advanced heart failure in the cardiac care unit (CCU) who are awaiting heart transplant. In early summer 2018, our hospital infection prevention (IP) department detected an uptick in CLABSI attributable to the CCU. After 9 months of zero CLABSI, two CLABSIs attributable to the CCU were identified during a 3 month period from November 2017-January 2018. Four additional CLABSIs were identified between May-July 2018 prompting an investigation by IP. Review of the 9 CLABSIs attributed to the CCU from May 2018 – June 2019 led IP to prioritize improving PAC insertion practices in our cardiac catheterization lab as a mean to reducing CLABSI (see table 1). MethodsIP performed 5 observations of PAC insertion in the cath lab. During the observations of skin preparation, the prep time was performed correctly 40% of the time, correct application 60% of the time and dry time 60% of the time (see table 2, Figure1). Interventions included scheduling a training day for all cath lab staff with the skin prep vendor, performing competency check-offs, and identifying super-users to train future staff. Furthermore, skin antiseptic utilization according the manufacturer's instructions for use was implemented, the coverage area for the applicator was reviewed and a chart for reference was provided.The staff was provided with posters on correct skin prep technique as a visual cue in the procedure room. ResultsSince the project was implemented in September 2019, there has been 1 CLABSI identified that was possibly related to a PAC inserted in the cath lab. During this time 3 CLABSIs were identified in the CCU but were felt to be unrelated to cath lab insertion. ConclusionSince the project was implemented in September 2019, there has been 1 CLABSI identified that was possibly related to a PAC inserted in the cath lab. During this time 3 CLABSIs were identified in the CCU but were felt to be unrelated to cath lab insertion.Disclosures All Authors: No reported disclosures
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.