Abstract
FreeStyle Libre 3 is the next generation FreeStyle Libre system with the same sensor tail but an on-body component that is about 70% smaller than Libre 2. We evaluated the accuracy of the FreeStyle Libre 3 system in people with diabetes ages 4 years or older at 4 U.S sites. This was a non-randomized, multi-center, single-arm study with 100 evaluable subjects (95 subjects aged 6 years or older) on intensive insulin therapy. Subjects 6 years or older participated in up to 3 in-clinic sessions of up to 8 hours each over the 14- day wear period to obtain YSI comparator data. No glycemic challenges were performed during these sessions. For 5 subjects in the 4-5 years age group, capillary fingerstick measurements were performed during one in-clinic session to obtain SMBG comparator data. System performance was evaluated in terms of percent accuracy with respect to venous plasma reference using the YSI2300 Stat glucose analyzer. Accuracy was characterized as the proportion of sensor results that were within ±15%, ± 20%, and ± 40% of their paired YSI values for glucose levels ≥ 70 mg/dL or within ± 15 mg/dL, ± 20 mg/dL, and ± 40 mg/dL of YSI for glucose levels < 70 mg/dL. Other accuracy metrics such as mean bias and mean absolute relative difference (MARD) of the FreeStyle Libre 3 System with respect to YSI were also evaluated and are presented in Table 1. The FreeStyle Libre 3 System showed 93.2 % of values within ±20mg/dL/±20% of the YSI reference with an overall MARD of 7.9% based on the data from the 95 subjects with YSI reference. Disclosure S. A. Karinka: Employee; Abbott Diabetes. R. L. Brazg: Research Support; Abbott Diabetes, Lilly Diabetes, Medtronic, Novo Nordisk, Roche Diagnostics, Senseonics. K. N. Castorino: Consultant; Lilly Diabetes, Research Support; Abbott Diabetes, Dexcom, Inc., Drawbridge Health, Inc., Eyenuk, Inc., Laxmi Therapeutic Devices, Medtronic, National Institute of Diabetes and Digestive and Kidney Diseases, Novo Nordisk, Speaker’s Bureau; Dexcom, Inc. D. R. Liljenquist: None. M. Kipnes: None. H. Liu: Employee; Abbott Diabetes. Funding Abbott Diabetes Care
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.