Abstract

Abstract Background Accurate and timely methods for the diagnosis of histoplasmosis in endemic resource-limited settings are largely lacking. Histoplasma galactomannan antigen detection by enzyme immunoassay (EIA) is the most widely used method for the diagnosis of acute pulmonary and disseminated histoplasmosis in the United States (USA). EIA methods have constraints in resource-limited settings including cost, turnaround time, and the need for large reference laboratories, leading to missed or delayed diagnoses and poor outcomes. Lateral flow assays (LFA) are practical methods that can be used in this setting for Histoplasma antigen detection. Methods Frozen urine specimens were submitted to MiraVista (MVista) for Histoplasma antigen EIA testing from three academic medical centers in highly endemic areas of the USA. They were also blinded and tested for the MVista Histoplasma LFA by skilled MVista technologists. Medical records were reviewed for clinical information. Patients were classified as controls or cases of histoplasmosis. Cases were divided into proven or probable, pulmonary, or disseminated, immune competent or immune suppressed, and mild, moderate, or severe. Results 352 subjects were enrolled, including 66 cases of histoplasmosis (44 proven, 22 probable) and 286 controls. Most of the cases were immunocompromised (68%). 76% had disseminated histoplasmosis. 6% were mild, 66% moderate, and 28% severe. A high degree of concordance was found between LFA and EIA results (kappa 0.837, OR 372.7, LR 204, p< 0.001). Overall, the sensitivity and specificity of the LFA were 78.8% and 99.3% respectively (kappa 0.84, p< 0.001). The sensitivity was higher in proven cases (93.2%), in patient with disseminated (94.7%), moderate (80%) and severe disease (94%), and those with galactomannan levels ≥ 2 ng/mL (97.7%). Specificity was 99.3% in proven cases, 99.3% in patient with moderate and severe disease, and 96.4% in those with galactomannan levels ≥ 2 ng/mL. Table 1. Statistical characteristics of the LFA test for histoplasmosis in different categories. PPV: Positive Predictive Value. NPV: Negative Predictive Value. EIA: Enzyme Immunoassay. The LFA test for histoplasmosis is more accurate in patients with high burden of infection. Conclusion The MVista Histoplasma galactomannan LFA may meet the need for accurate rapid diagnosis of histoplasmosis in resource-limited settings, especially in patients with relatively high disease burden, potentially reducing morbidity and mortality. Disclosures Melissa Minderman, Bachelor's Degree, Molecular Biology, MiraVista Diagnostics (Employee) Suphansa Gunn, Bachelor's Degree, psychology, MiraVista Diagnostics (Employee) Lawrence J. Wheat, MD, MiraVista Diagnostics (Employee)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call