Abstract

The present study aimed to assess gadoxetate disodium contrast-enhanced (CE) positron emission tomography (PET)/magnetic resonance imaging (MRI) with 68 Ga-DOTATOC and 11 C-5-Hydroxy-tryptophan (11 C-5-HTP) in comparison with iodine CE 68 Ga-DOTATOC-PET/computed tomography (CT) for neuroendocrine tumour imaging. Detection rate and reader's confidence were evaluated for each separate image volume: CE-CT, CE-MRI including diffusion-weighted imaging, 68 Ga-DOTATOC-PET performed at PET/CT, 68 Ga-DOTATOC-PET performed at PET/MRI and 11 C-5-HTP-PET, and for the three combined hybrid examinations 68 Ga-DOTATOC-PET/MRI, 11 C-5-HTP-PET/MRI and 68 Ga-DOTATOC-PET/CT. In 11 patients, 255 lesions were depicted. 68 Ga-DOTATOC-PET performed at PET/MRI depicted 72.5%, 68 Ga-DOTATOC-PET performed at PET/CT depicted 62.7%, 11 C-5-HTP-PET depicted 68.2% and CE-CT depicted 53% of lesions. 68 Ga-DOTATOC-PET performed at PET/MRI (P<0.001) and PET/CT (P=0.02), 11 C-5-HTP-PET (P<0.001) and MRI (P<0.001) were superior to CT. 68 Ga-DOTATOC-PET/MRI and 11 C-5-HTP-PET/MRI detected 92.5% and 92% of lesions, respectively, and both outperformed 68 Ga-DOTATOC-PET/CT (65%) (P<0.001). For liver metastasis imaging, MRI alone was unsurpassed (P<0.01) and 68 Ga-DOTATOC-PET/MRI and 11 C-5-HTP-PET/MRI outperformed 68 Ga-DOTATOC-PET/CT (P<0.001). For lymph node metastasis diagnosis, 68 Ga-DOTATOC-PET performed at PET/MRI and PET/CT and 11 C-5-HTP-PET detected 94%, 94% and 94% of lesions, respectively, and outperformed MRI and CE-CT alone (P<0.001). For bone metastasis imaging, 68 Ga-DOTATOC-PET performed at PET/MRI and PET/CT and 11 C-5-HTP-PET performed equally well (P=0.05) and better than MRI. Reader's confidence was better for 68 Ga-DOTATOC-PET/MRI and 11 C-5-HTP-PET/MRI than for 68 Ga-DOTATOC-PET/CT. The tumour maximum standardised uptake value and tumour-to-liver ratio were both approximately twice as high as for 68 Ga-DOTATOC than for 11 C-5-HTP. 68 Ga-DOTATOC-PET/MRI and 11 C-5-HTP-PET/MRI provided the highest detection rates and reader's confidence and were both superior to 68 Ga-DOTATOC-PET/CT, mainly because of the MRI component. The imaging contrast with 68 Ga-DOTATOC was superior to that of 11 C-5-HTP.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.