Abstract

In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.