Abstract
The effects of pre-heat temperature (65–95 °C) and holding time (5 and 25 s) on fouling of reconstituted skim milk at high-heat temperatures of 135–150 °C using a bench-top UHT plant were investigated. Fouling was monitored by observing the variation in overall heat transfer coefficient (OHTC) with time and consisted of an induction phase (non-fouling) and a decline phase (fouling). A significantly shorter run-time was obtained with pre-heating at 65 °C than with pre-heating at 75, 85 and 95 °C. A longer holding time (25 s) in the pre-heating section significantly increased the run-time of the plant compared with 5 s holding. The high-heat temperature also affected the OHTC and run-time; similar run-times were observed at 135, 140, 142 and 145 °C but at 150 °C there was no induction phase and fouling rapidly occurred. Overall, pre-heating at 85 °C or 95 °C for 25 s, combined with a high-heat temperature of 145 °C, and pre-heating at 95 °C for 25 s combined with high-heat temperatures of 142 °C, produced the longest run-times of the bench-top UHT plant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.