Abstract

A 232Th miniature fission counter probe was perfected with use of the Th depositing technique. A sensitivity of approximately 1×10-6 counts/n/cmcm2 was obtained for reactor fast neutron flux with a typical cylindrical counter (6mm O.D., 10mm sensitive length). The counter was applied to the measurement of the fast neutron flux distribution within a research reactor core. The fast neutron flux distribution thus measured with the counter provided results identical with that obtained from the activation of threshold foils. Depleted U fission counters with Cd-cover have in the past been used for fast neutron flux measurements. The 232Th fission counter can, however, be used without Cd-filter, with excellent resolution of thermal and epithermal neutrons.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.