Abstract

Parametric array loudspeaker (PAL) produces a highly directional sound beam due to the attribute of ultrasound used for carrier waves. Active noise control system with PAL has merit because it less causes spillover than that with normal loudspeaker. However, PAL still have serious problem in its sound quality because of harmonics. To solve this demerit, this paper propose a method using a adaptive filter to decrease harmonics sound pressure. In spite of simple process, we obtained good results by three cases experiment. These experimental date show this system is superior to conventional method such as Single-Sideband modulation (SSB) from two points of view. First, this system can control sound pressure both of the 2nd harmonics and intermodulation distortion. Second, the control effect is obtained on wide area with only a microphone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.