Abstract

Summary Standardized single-injection 3-station moving-table 3T contrast-enhanced MR angiography (CE-MRA) is reliable for stenosis detection and classification in peripheral arterial occlusive disease with equivalent diagnostic performance as 1.5T CE-MRA, while contrast-to-noise ratio significantly increased at 3T for identical contrast dosage. Background Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-MRA. Diagnostic performance of 3T versus 1.5T CE-MRA has not yet been described. The purpose of this study was to compare diagnostic accuracy of 3T CE-MRA in POAD in an equivalence trial with 1.5T CE-MRA, with conventional digital subtraction angiography (DSA) as the standard of reference. Methods In nineteen patients (13 men; mean age 69 years), DSA and standardized single-injection 3-station moving-table CE-MRA with equivalent acquisition protocols and contrast dosage were performed at 3T and 1.5T MRI (Philips, Best, the Netherlands). For CE-MRA, 0.2 mmol/kg body weight gadoterate meglumine was injected, with the first half of the bolus at 2 mL/s and second half at 0.6 mL/s. At 1.5T, a quadrature body coil (QBC) was used for imaging pelvic and thigh stations and a 4-element phased array coil for calf station. At 3T, a QBC was used in all three stations. DSA was performed using iomeprol injection at variable volumes and flow rates depending on the arterial segment. The arterial tree in each patient was divided into 27 segments, infrarenal aorta, common and external iliac arteries, common and superficial femoral arteries, popliteal arteries in thigh and calf station, tibiofibular trunk, proximal and distal halves of the anterior and posterior tibial arteries and peroneal arteries. Visual stenosis classification was performed in consensus by two radiologists in blinded manner using the following categories: class 1 (0%-stenosis), 2 (1-50%), 3 (51-75%), 4 (76-99%) and 5 (100%). Quantitative analysis of contrast-to-noise ratio (CNR) was performed for the external iliac artery and the superficial femoral artery. Results

Highlights

  • Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD)

  • In nineteen patients (13 men; mean age 69 years), digital subtraction angiography (DSA) and standardized single-injection 3-station moving-table CE-MRA with equivalent acquisition protocols and contrast dosage were performed at 3T and 1.5T MRI (Philips, Best, the Netherlands)

  • At 3T, a quadrature body coil (QBC) was used in all three stations

Read more

Summary

Introduction

Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-MRA. Diagnostic performance of 3T versus 1.5T CE-MRA has not yet been described. The purpose of this study was to compare diagnostic accuracy of 3T CE-MRA in POAD in an equivalence trial with 1.5T CE-MRA, with conventional digital subtraction angiography (DSA) as the standard of reference

Objectives
Methods
Results
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.