Abstract

IntroductionThe purpose of this study was to evaluate the ability of the XP-endo Shaper instrument (FKG Dentaire, La Chaux-de-Fonds, Switzerland) during the removal of root fillings from oval-shaped canals. M-Wire Reciproc and Reciproc Blue systems (VDW, Munich, Germany) were used as reference instruments for comparison, and micro–computed technology was used as an analytical tool. MethodsThirty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (eg, volume, aspect ratio, and 3-dimensional configuration) after scanning procedures. The canals were prepared with M-Wire Reciproc R25 instruments and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) using the continuous wave of condensation technique. Then, the sample was allocated into 3 experimental groups (n = 10) according to the retreatment protocol used: M-Wire Reciproc, Reciproc Blue, and XP-endo Shaper. M-Wire Reciproc R25, Reciproc Blue R25, and XP-endo Shaper instruments were used to remove the root fillings. Apical enlargement was performed with M-Wire Reciproc R40, Reciproc Blue R40, and BioRace BR5 (FKG Dentaire) instruments. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after apical enlargement. The percentage volumes of root filling reduction in relation to the instrumented canals at both time points (before and after apical enlargement) were calculated and considered for statistical analysis. Data were analyzed statistically with a significance level of 5%. ResultsReciproc Blue presented significantly lower removal of filling material compared with the XP-endo Shaper (Tukey test, P < .05). No difference was detected either between M-Wire Reciproc and Reciproc Blue (Tukey test, P > .05) or M-Wire Reciproc and XP-endo Shaper (Tukey, P > .05). The increase of apical enlargement significantly improved the removal of root fillings from the root canals (P < .05); this effect was similar for all systems (time point × file system, P > .05). ConclusionsThe XP-endo Shaper instrument showed a higher percentage of root filling removal, but no differences were observed comparing M-Wire Reciproc with the XP-endo Shaper or Reciproc Blue. The increase of apical enlargement improved the removal of root fillings in all groups. None of them was able to render root canals completely free from root fillings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call