Abstract

AbstractThis paper presents finite element (FE) investigations of the seismic response of a bridge incorporating a base rocking steel pier. The pier consists of a circular steel tube, circular end plates, posttensioned (PT) tendon(s), and supplemental energy dissipation devices, and is configured to rock at its interface with the foundation. The main characteristic of such a pier is its ability to ensure small residual drifts after undergoing inelastic deformations during cyclic loading. The system has a tendency to close the gap due to the presence of superstructure dead load (DL) and tendon posttensioning force. Using experimental data, the calibration of the FE procedure is done at the material, component, and global system levels. The FE model of a prototype bridge is developed with the rocking pier modelled by continuum elements while superstructure, bearing units, abutment walls and backfill material modelled by discrete elements. The analysis procedure includes the application of one or two earthquake excitations, traffic loads, and braking force. The varied parameters are the diameter‐to‐thickness ratio of the column, presence of a PT tendon, addition of supplemental energy dissipaters (EDs), base plate dimensions, height of ED chairs, and ED strength. The results of dynamic FE studies demonstrate that a bridge utilizing such a pier has the potential to undergo consecutive earthquakes without sustaining significant damage and return to its original position without requiring abutment component stiffness and strength.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have