Abstract

Orbital volume evaluation is an important part of pre-operative assessments in orbital trauma and congenital deformity patients. The availability of the affordable, open-source software, OsiriX, as a tool for preoperative planning increased the popularity of radiological assessments by the surgeon. A volume calculation method based on 3D volume rendering-assisted region-of-interest computation was used to determine the normal orbital volume in Taiwanese patients after reorientation to the Frankfurt plane. Method one utilized 3D points for intuitive orbital rim outlining. The mean normal orbital volume for left and right orbits was 24.3±1.51 ml and 24.7±1.17 ml in male and 21.0±1.21 ml and 21.1±1.30 ml in female subjects. Another method (method two) based on the bilateral orbital lateral rim was also used to calculate orbital volume and compared with method one. The mean normal orbital volume for left and right orbits was 19.0±1.68 ml and 19.1±1.45 ml in male and 16.0±1.01 ml and 16.1±0.92 ml in female subjects. The inter-rater reliability and intra-rater measurement accuracy between users for both methods was found to be acceptable for orbital volume calculations. 3D-assisted quantification of orbital volume is a feasible technique for orbital volume assessment. The normal orbital volume can be used as controls in cases of unilateral orbital reconstruction with a mean size discrepancy of less than 3.1±2.03% in females and 2.7±1.32% in males. The OsiriX software can be used reliably by the individual surgeon as a comprehensive preoperative planning and imaging tool for orbital volume measurement and computed tomography reorientation.

Highlights

  • Quantitative determination of orbital volume is valuable to the evaluation and management of many conditions affecting the orbit

  • The principal goal of surgical intervention in trauma or congenital deformity is restoration of the bony anatomy of the orbital cavity. This should result in correction of globe position and assist in correcting visual manifestations such as diplopia [1]

  • Frankfurt plane was located by using the 3D Multiplanar Reconstruction (3D MPR) volume rendering tool and 3D point function of OsiriX

Read more

Summary

Introduction

Quantitative determination of orbital volume is valuable to the evaluation and management of many conditions affecting the orbit. 3D-Assisted Quantitative Assessment of Orbital Volume dysplasia, Pfeiffer syndrome), and traumatic orbital fractures. The principal goal of surgical intervention in trauma or congenital deformity is restoration of the bony anatomy of the orbital cavity. This should result in correction of globe position and assist in correcting visual manifestations such as diplopia [1]. Empirical assessments formed the basis of decision-making within the operating room. This often results in over or under-correction, and clinical experience demonstrates that globe position post-operatively is highly unpredictable [2]

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.