Abstract

Low cycle fatigue tests on SCM435 steel tempered at 580℃ were carried out under the frequencies of 0.2, 2 and 20Hz with specimens containing a small artificial hole. The fatigue life of the hydrogen charged specimens decreased in comparison with the uncharged specimens. The acceleration of fatigue crack growth rate was observed at ΔK<40MPa√<minf=20Hz>, ΔK<60MPa√<minf=2Hz> and ΔK<100MPa√<minf=0.2Hz>. Facets were formed on the fracture surface of hydrogen charged specimens in the ΔK region where the crack growth rate was accelerated. Many slip bands were observed at the crack tip of the uncharged specimens. On the other hand, slip bands were not clear the hydrogen-charged specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.