Abstract

Abstract Background Data regarding clinical outcomes of biodegradable polymer drug-eluting stent (BP-DES) versus second-generation durable polymer drug-eluting stent (DP-DES) in patients undergoing percutaneous coronary intervention (PCI) are inconclusive. Purpose We aimed to perform a meta-analysis to investigate the clinical outcomes of BP-DES compared with second-generation DP-DES in patients who have undergone PCI. Methods We searched PubMed, MEDLINE, EMBASE, and Cochrane databases through January 2019 for randomized controlled trials comparing BP-DES with second-generation DP-DES in patients treated with PCI. All-cause death, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), target lesion revascularization (TLR), definite/probable stent thrombosis (ST) were compared between the groups. Additionally, a landmark analysis with the landmark set at 1 year and a subgroup analysis according to stent characteristics were performed. Results Data from 23 trials including 28802 randomized patients were analyzed. At a median follow up of 3.1 years, no significant differences were found in terms of all-cause death (odds ratio [OR] 1.05, 95% confidence interval [CI] 0.95–1.16), cardiac death (OR 1.01, 95% CI 0.87–1.17), MI (OR 0.92, 95% CI 0.82–1.03), TVR (OR 0.97, 95% CI 0.86–1.11), TLR (OR 0.97, 95% CI 0.85–1.11), and definite/probable ST (OR 0.86, 95% CI 0.70–1.07) between the groups. Landmark analysis showed that there were similar risks in all-cause death (OR 1.04, 95% CI 0.93–1.17), cardiac death (OR 1.11, 95% CI 0.92–1.36), MI (OR 0.94, 95% CI 0.79–1.13), TVR (OR 0.95, 95% CI 0.73–1.23), TLR (OR 1.00, 95% CI 0.80–1.24), and definite/probable ST (OR 0.92, 95% CI 0.67–1.28) between the groups. The similar tendency of any study endpoints between the groups was consistent in the subgroup, including stent platform (stainless steel vs. alloy), the drug coating distribution (abluminal vs. circumferential), the polymer degradation period (<6 months vs. >6 months), or the drug release duration (<6 months vs. >6 months) of BP-DES, or the DAPT duration (≥6 months vs. ≥12 months). However, the uses of BP-DES with sirolimus-eluting (OR 0.84, 95% CI 0.72–0.98) or ultrathin strut (defined as <70μm; OR 0.81, 95% CI 0.68–0.97) were predictive for lower risk of MI. Clinical outcomes Conclusions In our updated meta-analysis, BP-DES implantation was associated with comparable clinical outcomes compared with second-generation DP-DES implantation. However, PCI with ultrathin biodegradable polymer sirolimus-eluting stent could reduce the risk of MI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.