The ventricular septum has increased numbers of insulin receptors. Isoxsuprine (ISX) has been reported to cause increased cord blood insulin. To demonstrate whether an association between ISX exposure, hyperinsulemia and ASH occurred Echocardiography (EC) was performed on 30 infants who had ISX exposure and 25 control infants. Normal septal thickness is 3-4 mm.The control septal thickness was .38±.04. The ISX septal thickness was .55±.13. These are significantly different at p < .005.The ISX treated infants were larger, had thicker ventricular septae and had higher cord insulin levels than non or partially treated controls. ISX as a tocolytic agent may have a similar effect on the fetus as maternal diabetes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.