Ultrasonic Velocity Profiler (UVP) is a powerful tool to measure an instantaneous velocity profile especially on a velocity measurement of an opaque liquid flow, such as liquid metal. In this study, UVP is applied to a velocity field measurement of a fluid flow of Lead Bismuth Eutectic (LBE) in Accelerator Drive System (ADS). We performed velocity measurement on the centerline of the loop and confirmed basic performance of the loop. It was found that there was intermittent release of eddy from the re-circulation region formed on a wall surface of an inner cylinder and behind the edge. We made then a measurement for an angular direction of circumference around the central axis and observed 3-dimensional structure of LBE flow of the loop. From these results, we made clear that UVP is highly effective in a measurement of the flow field of liquid metal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.