Abstract

Time of Wetness CTOW), an index of moisture deterioration factors suffering building materials, was monitored by a dew detector: EKO MH-045 on south/30 deg tilted plane at outdoor exposure site in Tsukuba, Ibaraki, for a year. Ratio of Dewing is expressed as a multiTegression equation including relative humidity, ambient temperature, and wind speed/direction. Referring to the meteorological data observed around Japan for 1991-2000, yearly total of TOW was plotted on a map to be discussed on the local difference. Another estimated TOW based on previous ISO's criteria is less than those shown in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.