Abstract

Study designTwo-center retrospective cohort study.ObjectiveThe aim of this study is to investigate the clinical effectiveness and safety of the MCGR hybrid in terms of spinal growth, 3D correction, balance, and complications.Summary of background dataThe magnetic-controlled growing-rod (MCGR) growth instrumentation method has gained popularity for early onset scoliosis (EOS) treatment in the past years due to the non-invasiveness of the subsequent interval elongation procedures. To improve 3D correction and reduce the costs, we combined a single concave MCGR with a sliding rod on the convex side to control the apex.MethodsA retrospective cohort study of 18 EOS children with an average 3-year follow-up (range 2.0–3.7) from two European spine centers treated with the single MCGR hybrid concept; 14 primary and 4 conversion cases. The primary and conversion cases were both evaluated preoperatively, postoperatively, 1 year, 2 years, and last follow-up.ResultsMean age was 9.9 (SD ± 2.9 years). The average frontal Cobb angle was reduced from mean 65° to 30° postoperatively, and had increased to 37° at latest follow-up. Rotation of the apical vertebra improved from mean 27° to 20° postoperatively which was partially lost to 23°. Kyphosis and lordosis both increased by an average of 5° during the time of follow-up. Spinal balance was improved. The post-implantation T1–S1 spine growth rate averaged 10 mm/year at last follow-up. There were 13 implant-related complications in 6 out of 18 patients. No screw pull-outs and nor surgical site infections were registered.ConclusionsThis is the first medium-term results of a single MCGR hybrid construct. Maintenance of correction and growth are reasonable, and the complication rate is relatively low as compared to bilateral MCGR application.Level of evidenceIII.

Highlights

  • Materials and methodsProgressive early onset scoliosis (EOS) can become a hazard to pulmonary development and function [1, 2]

  • We found that the average time until conversion was 1.7 years

  • We believe that an age between 8 and 10 years and failed bracing is the ideal indication. This is the first report on medium-term results of a hybrid concept that consists of a single magnetic-controlled growing-rod (MCGR) for concave distraction combined with a contralateral passive gliding rod construct with apical control

Read more

Summary

Introduction

Progressive early onset scoliosis (EOS) can become a hazard to pulmonary development and function [1, 2]. Different “growth-friendly systems” and implants have been developed to control the scoliosis deformity and allow for continuous spinal growth and thereby support the truncal development. Controlled growing rods (MCGRs) (Magec, NuVasive, San Diego, CA, USA) were introduced about 10 years ago with the first publication in 2012 [5]. It is recommended for dual or single rod application according to the needs of the individual patient. MCGRs allow for non-invasive distraction of the rod construct by electromagnetic stimulation without sedation

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.