Abstract

This study evaluated the usefulness of 3-Tesla magnetic resonance (MR) spectroscopy in patients with non-Hodgkin's lymphoma (NHL) undergoing bone marrow transplantation (BMT). Twelve NHL patients who were candidates for BMT underwent three MR examinations of the lumbosacral spine: before ablative therapy for BMT, 15±4 days and 54±24 days after BMT. The MR study was supplemented by spectroscopic analysis. The lipid content was calculated and expressed as a percentage of lipid signal intensity relative to total signal intensity [fat fraction (FF)]. In the first MR study, the FF was 62.5±7%, in the second it was 70.75±5% and in the third it was 75±1%. We observed a statistically significant difference between FF values calculated at the various MR studies (p=0.02) and between red blood cell count (p=0.017), platelet count (p=0.003) and haematocrit (p<0.001) at the three MR studies. FF had a statistically significant correlation with the number of circulating platelets (p<0.01) MR spectroscopy of the bone marrow of NHL patients undergoing BMT is noninvasive and highly sensitive for characterising and monitoring bone marrow after BMT.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call