Abstract

Machine design typically concentrates on the main magnetic and electric circuits while various additional losses are evaluated only by simple empirical equations. The objective of this paper is to examine the importance of the additional losses in the stator end region and in the housing of a 3.1 MW permanent-magnet wind generator. Stator stack clamping ring and finger plate losses are investigated using a 3-D finite element method. 2-D FEM analysis of the stator supporting housing losses is also performed. Two common mechanical component materials are analyzed in the 3-D studies; construction steel and stainless steel. The results show that failure to consider stator end areas and stator supporting constructions at the design stage can result in unwanted additional losses and affect machine efficiency. Indirect verification of the results is provided by efficiency measurements of different versions of the real 3.1 MW machine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.