Abstract

The exit surface of a lens is designed using a three-dimensional free-form expression in order to easily modify a curved surface. This enables the design of numerical values and mathematical things using three-dimensional free-form expression, and enhances precision because it can be fine-tuned via numerical control. The standard of “Classification of Luminaire Light Distribution” for outdoor lighting fixtures by IESNA is adopted in order to examine the correlation between three-dimensional free-form surface expression and lighting performance. The variation of light distribution type and range is analyzed using the values of maximum light intensity and 50% light intensity. The actual tolerance occurs owing to parameters such as the thickness of the lens, the distance between LEDs, and the movement of the center of the incident surface; the effects of changes in these parameters on the performance are compared and analyzed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.