Abstract

The article brings a brief revision of the two-degree-of-freedom (2-DoF) internal model control (IMC) and the 2-DoF Smith-Predictor-based (SP) control of unstable systems. It shows that the first important reason for distinguishing between these approaches is the limitations of the control action. However, it also reminds that, in addition to the seemingly lucrative dynamics of transients, the proposed approaches can conceal a tricky behavior with a structural instability, which may manifest itself only after a longer period of time. Instead, as one of possible reliable alternatives, two-step IMC and filtered Smith predictor (FSP) design are applied to unstable first-order time-delayed (UFOTD) systems. Firstly, the 2-DoF P controller yielding a double real dominant closed loop pole is applied. Only then the 2-DoF IMC or FSP controllers are designed, providing slightly slower, but more robust transients. These remain stable even in the long run, while also showing increased robustness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.