Abstract

Abstract The Wadi El Natrun area is characterized by a very complicated geological and hydrogeological system. 45 vertical electrical soundings (Schlumberger array) were measured in the study area to elucidate the peculiarity of this unique regime, specifically the nature of waterless area. 2D and 3D resistivity inversion based on the finite element technique and regularization method were applied on the data set. 2D and 3D model resolution was investigated through the use of the Depth and Volume of Investigation Indexes. A very good matching was found between the zones of high resistivity, the waterless area, and the non-productive wells. The low resistivity zones (corresponding to Lower Pliocene clay) were also identified. The middle resistivity fresh water aquifer zones were recognized. Available results can assist in the aquifer management by selecting the most productive zone of groundwater.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.