Abstract
The results of experimental study on the formation of high-current electron beams using three-electrode system are presented. This system enables to create a diffusive obstructed glow discharge in a pulsed regime with an amplitude of applied voltage up to 25 kV. The influence of such experimental parameters as the pressure of plasma forming gas and the amplitude of applied voltage on the obstructed glow discharge duration was investigated. Both the transverse and the longitudinal structure of formed electron beam was determined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.