Abstract

Abstract Background The wearable cardioverter defibrillator (WCD) has been shown to be useful during transient periods of high sudden cardiac death risk, and the issue of compliance recently pointed out. This Registry was designed to provide real-world data on WCD use in France, in terms of compliance, potential adverse events, as well as efficacy. Methods and results Multicenter evaluation (WEARIT FRANCE Registry) was conducted in France between January 2017 and March 2018. Overall, 1,157 patients were analyzed: 950 with ischemic heart disease (82%, including 647 patients after myocardial infarction), 119 after ICD explant (10%), and 88 pre-transplant (8%). The median age was 61 years; the median ejection fraction was 25%. Median WCD wear time was 62 days, with median daily use of 23.4 hours. Less than 1% of patients did not wear WCD at least 4 hours per day. During follow-up, a total of 42 sustained ventricular tachyarrhythmias (VT/VF) occurred in 36 patients, of whom 50% (n=18) received appropriate WCD shocks, giving an incidence of appropriate therapy of 1.56%. The rate of all VT/VF episodes were 3.1% among patients with ischemic cardiomyopathy (n=29/950) versus 3.4% for the others (n=7/207). Of the ischemic patients wearing beyond 30 days (N=784), 5 received appropriate therapy of VT/VF episodes. Overall shock survival was 100%. At the end of the WCD period, 586 patients (51%) were implanted with an implantable cardioverter defibrillator. Eight patients (0.69%) received inappropriate WCD shocks. Regarding the apparent very low proportion of women considered for WCD therapy, we aimed to appreciate in which extent Conclusions In this multicenter nationwide WCD evaluation, 3.1% of patients presented with sustained VT/VF with 47% of those patients developing VT/VF after 30 days. The incidence of inappropriate therapy was low. The compliance to WCD in this real life evaluation was very high. These data suggest that the WCD, when worn appropriately, may be helpful in the arsenal to protect high-risk patients against SCD, especially in case of transient risk situations. Acknowledgement/Funding Zoll

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.