Abstract

Introduction Atrial fibrillation (AF) is the most common persistent cardiac arrhythmia. The impact of AF on quality of life (QoL) is significant, and much has related to the achieved resting ventricular rate (VR). Strategies to control VR can improve QoL in AF patients. However, the ideal VR target remains unclear. Therefore, we aimed to identify the ideal VR target by comparing the QoL of AF patients with different VR cut-off means from the 24-hour Holter (Holter). Methods A cross-sectional study was conducted on AF patients in the international normalized ratio (INR) clinic at Hospital Universiti Sains Malaysia. Patients were fixed with a Holter monitor while QoL was measured using the SF-36v2 Health Survey. Patients were repeatedly divided into mean 24-hour Holter VR above and below 60, 70, 80, 90, and 100 beats per minute (bpm). The differences in the total SF-36v2 score and its components were examined. Results A total of 140 patients completed the study. There was a significant difference in physical role, vitality, mental health, mental component summary, and total SF-36v2 scores for VR above and below 90 bpm. The total SF-36v2 score difference was also significant in the covariate analysis, while other VR cut-offs (60, 70, 80, and 100 bpm) did not show significant changes in total SF-36v2 scores. Conclusion Significant differences were observed in the QoL scores among AF patients, with a cut-off VR of 90 bpm favoring patients with the higher rate. Hence, higher VR is better in terms of QoL among stable AF patients.