Abstract

Boiler as the steam generator is usually utilized as a turbine drive and other industrial processes. Boiler needs good treatment and surveillance to keep its best performance. Boiler water (BW) and boiler feed water (BFW) quality control is essential in boiler maintenance since it preserves boiler from crust, corrosion, and carry over, moreover, it also prevents boiler pipe to break. Boiler maintenance in sugar refinery factory is carried out by controlling the quality of BFW, Chemical injection (inner maintenance) and blowdown of boiler water. BFW mineral content (SiO 2 , total hardness) is maintained as small as possible using a softener (cation resin) or demineralization unit (cation and anion resin). Chemical injection is performed by the addition of soda in order to control the pH of boiler water. Phosphate addition aims to tie up total hardness level which is caused by concentration process of water boiler and slipped of hard water from BFW. Blowdown process has purpose to reduce crust and corrosion caused by mineral concentrate inside boiler. The experiment was conducted by controlling pH of BFW from 7.5-8.5, maximum total hardness at 3 ppm, maximum SiO 2 concentration at 3 ppm and maximum Total Dissolve Solid (TDS) at 100 ppm while BW was controlled its pH at 10.5-11, maximum total hardness at 20 ppm, maximum SiO 2 concentration at 50 ppm, maximum Total Dissolve Solid (TDS) at 2000 ppm, and residual phosphate ion between 4 – 10 ppm. The experiment time was adjusted as a milled day or about for 140 days. The result of the experiment showed that the treatment had a good impact on the condition of the boiler drum pipe.

Highlights

  • Abstract⎯ Boiler as the steam generator is usually utilized as a turbine drive and other industrial processes

  • The fluid that stream in fire tube boiler is combustion gas containing thermal energy that soon to be transferred to Boiler water (BW) through heating surface

  • Water tube boiler had water streamed in the pipe, thermal energy is obtained from furnace room outside the pipe [3]

Read more

Summary

21 Bar Yoshimin Boiler Maintenance with Controlling Residual Phosphate

Abstract⎯ Boiler as the steam generator is usually utilized as a turbine drive and other industrial processes. Boiler water (BW) and boiler feed water (BFW) quality control is essential in boiler maintenance since it preserves boiler from crust, corrosion, and carry over, it prevents boiler pipe to break. Boiler maintenance in sugar refinery factory is carried out by controlling the quality of BFW, Chemical injection (inner maintenance) and blowdown of boiler water. Chemical injection is performed by the addition of soda in order to control the pH of boiler water. Phosphate addition aims to tie up total hardness level which is caused by concentration process of water boiler and slipped of hard water from BFW. Blowdown process has purpose to reduce crust and corrosion caused by mineral concentrate inside boiler. The result of the experiment showed that the treatment had a good impact on the condition of the boiler drum pipe

INTRODUCTION1
Experimental
RESULT
Boiler Feed Water
Boiler Water pH pH BFW pH BW
50 M Alkanity
CONCLUSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.