Abstract

This paper reports on fabrication and characterization of atomic force microscopy (AFM) dual probe with narrow-gapped dual Si tip and dual cantilever with sputtered Fe_<60>Pd_<40> magneto-strictive film for switching of the cantilevers. A 600 nm-gapped dual Si tip was fabricated in a device layer of a silicon-on-insulator (SOI) wafer through self-align fabrication process based on narrow Si trench etching, refilling, polish-back, and Si crystalline anisotropic etching. After the dual Si tip fabrication. Fe_<60>Pd_<40> film (1μm)/ Si (2μm) dual cantilever was formed by MEMS fabrication process. The cantilevers were orthogonally located. By static magnetic flux of 300 Gauss along a cantilever, it was deflected to 1 μm by positive magneto-striction of the FePd film. In particular, the other cantilever orthogonal to the magnetic flax shows no deflection, resulting in sufficient individual actuation of the dual cantilever for switching.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.