Abstract

This paper deals experimentally and analytically with the design of a dynamic absorber to quench galloping phenomena generated in transmission lines in the condition of storong wind. Galloping phenomena are one of self-excited vibration called flow-induced vibration, and it is caused by a hydrodynamic coefficient obtained from lift force and drag having a negative damping. As a countermeasure, a dynamic absorber was experimentally applied to a simple experimental test rig composed of the main system supported by four springs. And, the simple analytical model of galloping was set up. The dynamic absorber was applied also analytically. It was found by the experiments and analysis that the natural frequency of the dynamic absorber should be tuned near the galloping frequency and the optimum damping of the dynamic absorber exists to quench the galloping. These results qualitatively agreed with experimentally and analytically.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.