Abstract
BackgroundCeftazidime and avibactam (CAZ-AVI) diffusion disks have been widely used in hospitals and clinical laboratories in the United States for susceptibility testing of infections caused by Enterobacteriaceae and Pseudomonas aeruginosa. A few cases of high error rates and overcalling of resistance in some carbapenem-resistant Enterobacteriaceae (CRE) isolates have been reported. The purpose of this study was to evaluate the performance of CAZ-AVI diffusion disks made by two manufacturers in comparison with that of the standard broth microdilution (BMD) method for susceptibility testing against a large collection of CRE.MethodsA panel of 110 meropenem nonsusceptible Enterobacteriaceae clinical isolates, including 98 Klebsiella pneumoniae, eight Enterobacter cloacae, and four Escherichia coli were tested using CAZ-AVI (30/20 µg) diffusion disks manufactured by Hardy Diagnostics (Hardy) and BD Biosciences (BD). These isolates harbored various carbapenemase genes including KPC-2, KPC-3, VIM, NDM, OXA, ESBL, and altered OmpK35 and OmpK36. The same isolates were tested for susceptibility to CAZ-AVI by BMD using a custom-made Trek panel. Correlation between minimal inhibitory concentration (MIC) and disk diffusion inhibition zones was assessed based on Clinical and Laboratory Standards Institute (CLSI) breakpoints and error rate analysis.ResultsOverall disk diffusion inhibition zones correlated well with MIC for disks manufactured by both Hardy and BD according to CLSI CAZ-AVI breakpoints (susceptible/resistant): MIC ≤8/4/≥16/4 µg/mL, disk diffusion ≥21/≤20 mm. Error rates were low for the Hardy disks grown on Hardy and BD Mueller–Hinton agar (MHA) with 0.9% very major errors (VME)/1.8% major errors (ME) and 1.8% VME/5.5% ME, respectively. The error rates for BD disks grown on Hardy and BD MHA plates were 1.8% VME/0% ME and 1.8% VME/6.4 ME, respectively. ME rates appeared to be lower when Hardy MHA plates were used for both Hardy and BD disks.ConclusionCAZ-AVI (30/20 µg) disks manufactured by Hardy and BD performed well in susceptibility testing against a challenging set of CRE isolates. These data showed good categorical agreement between disk diffusion and BMD methods. Error rates were lowest when Hardy MHA plates were used for both Hardy and BD disks.Disclosures L. Y. Lin, Allergan: Employee, Salary. I. A. Critchley, Allergan (at time of study): Employee, Salary.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.