Abstract

The Engineering and Test Branch within the Division of Operations and Maintenance of the California Department of Water Resources (DWR) and U.S. Army Corps of Engineers (USACE), Sacramento District, tasked the Sensor Integration Branch (SIB) at the Engineer Research and Development Center (ERDC) to perform nondestructive testing (NDT) on the trunnion anchor rods at Oroville Dam through the use of ultrasonic guided waves. This is the fourth year of this NDT. The results of the testing are presented along with qualitative analysis in determining whether a rod is intact or compromised. Analysis is based upon the expected results from other rods at the site, knowledge of rod response at other sites, data gathered from the trunnion rod research test bed at ERDC, and comparison to the previous year’s effort.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call