Abstract

This paper reports on the results of the optimization of the cross-sectional shape of a magnet coil system including an MHD channel. This optimization was carried out for a 200-MWe supersonic Faraday-type MHD generator. It was shown that the channel length can be shortened more than 30 percent, without the decrease of the enthalpy extraction by the optimization of the coil shape from the crescent shape coil producing a uniform magnetic field. It was estimated also that the capital cost for a commercial MHD/steam combined plant can be decreased more than 6 percent by this coil shape optimization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.