Abstract

Planar laser-induced fluorescence (PLIF) of hydroxyl (OH) and formaldehyde (CH2O) radicals was performed alongside stereo particle image velocimetry (PIV) at a 20kHz repetition rate in a highly turbulent Bunsen flame. A dual-pulse burst-mode laser generated envelopes of 532nm pulse pairs for PIV as well as a pair of 355nm pulses, the first of which was used for CH2O PLIF. A diode-pumped solid-state Nd:YAG/dye laser system produced the excitation beam for the OH PLIF. The combined diagnostics produced simultaneous, temporally resolved two-dimensional fields of OH and CH2O and two-dimensional, three-component velocity fields, facilitating the observation of the interaction of fluid dynamics with flame fronts and preheat layers. The high-fidelity data acquired surpass the previous state of the art and demonstrate dual-pulse burst-mode laser technology with the ability to provide pulse pairs at both 532 and 355nm with sufficient energy for scattering and fluorescence measurement at 20kHz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call